A low-cost IoT-based accumulation chamber for measuring diffuse CO2 fluxes: calibration and field validation at Nea Kameni volcano (Santorini)
Tipo Dataset
Classificazione Dati Geochimici (analisi geochimiche di rocce, acque e gas)
Diffuse Degassing
Carbon Dioxide
Volcanology
Volcanic Monitoring
Geochemistry
This dataset, provided as a three-sheet spreadsheet, details the laboratory calibration of an IoT accumulation chamber and the subsequent fieldwork.
- Sheet 1 (Calibration_data) contains calibration data, including simulated fluxes, the measured rate of CO2 concentration change observed by the accumulation chamber, and the resulting recalculated measured fluxes.
- Sheet 2 (Calibration_raw_data) contains the raw CO2 concentration time-series data for each individual measurement trial conducted during the calibration process.
- Sheet 3 (Nea_Kameni_data) contains diffuse flux data and geographic coordinates from fieldwork carried out at the Nea Kameni volcano in Santorini.
Data e Risorse
Questo dataset non ha dati
Citare come
Tamburello G., Cardellini C., Rouwet D., Todesco M. (2026). A low-cost IoT-based accumulation chamber for measuring diffuse CO2 fluxes: calibration and field validation at Nea Kameni volcano (Santorini) (Version 1.0) [Data set]. Istituto Nazionale di Geofisica e Vulcanologia (INGV). https://doi.org/10.13127/santorini/iot-accumchamb.1